Sign In | Join Free | My mainevillemotors.com
mainevillemotors.com
Products
Search by Category
Home > Agricultural Product Stock >

Hot Water Air Sourced Heat Pump Air Cooled Chilled Water System

Categories Air Cooled Water Chiller
Brand Name: HIGOLDEN
Model Number: HLWH-360DHM-630DHM
Certification: CE
Place of Origin: GuangDong
MOQ: 1 Unit
Price: Negotiable
Payment Terms: T/T, Western Union, L/C, MoneyGram
Supply Ability: 500pcs per month
Delivery Time: 10 working days after received your payment
Packaging Details: Wooden Case
Heating capacity(KW): 387-675
Power supply: 380v-50hz-3ph
Cooling capacity(KW): 358-632
Condenser: Ripple Aluminum Fins Around Copper Pipe
Certificate: CE
Mount type: free standing
Chilled water flow(m³/h): 61.6-108.7
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Hot Water Air Sourced Heat Pump Air Cooled Chilled Water System


    Hot Water Air Sourced Heat Pump Air Cooled Chilled Water System


    Model HLWH~

    360DHM

    390DHM

    460DHM

    490DHM

    540DHM

    590DHM

    630DHM

    Rated Cooling

    Capacity

    Cooling

    Capacity (KW)

    358

    391

    464

    490

    536

    586

    632

    Comp.

    Input Power (KW)

    116.4

    127.6

    141.0

    148.2

    164.8

    180.4

    197.8

    Rated Heating

    Capacity

    Heating

    Capacity (KW)

    387

    423

    491

    518

    569

    622

    675

    Comp.

    Input Power (KW)

    114.4

    125.6

    138.3

    145.4

    161.7

    176.9

    194.4

    Refrigerant

    R407C

    Power Supply

    380V/ 3ph/ 50Hz

    Safety Protection

    Phase reversion protection,

    Phase lack protection,

    Overload current protection,
    Discharge air temp. protection,

    Low & High pressure protection,

    Low temp. protection,

    Water flow protection.

    Number of

    Refrigeration Circuit

    2

    Capacity Control (%)

    0, 25, 37.5, 50, 62.5, 75, 87.5, 100

    Refrigerant Charge (Kg)

    114

    122

    146

    150

    164

    178

    196

    Air Cooled

    Heat Exchanger

    Ripple Aluminum Fins Around Copper Pipe

    Water Cooled

    Heat Exchanger

    Dia.of Pipe (inch)

    5"

    5"

    3"×2

    3"×2

    4"×2

    4"×2

    4"×2

    Water Side

    Max Pressure (MPa)

    1

    Chilled

    Water Flow(m3/h)

    61.6

    67.2

    79.8

    84.3

    92.2

    100.8

    108.7

    Water

    Pressure Drop (kPa)

    42

    54

    44

    52

    54

    55

    65

    Flow of

    Hot Water(m3/h)

    66.6

    72.7

    84.4

    89.1

    97.9

    107.0

    116.1

    Axial Fan

    Air

    Flow×1000m3/h

    172.8

    172.8

    230.4

    230.4

    230.4

    321.6

    321.6

    Power×Qty (KW)

    1.2×12

    1.2×12

    1.2×16

    1.2×16

    1.2×16

    2.0×16

    2.0×16

    Running

    Noise dB(A)

    75

    75

    75

    75

    75

    75

    75

    Total

    Weight (Kg)

    5620

    5800

    6240

    6430

    6600

    6960

    7320

    Running

    Weight(Kg)

    6040

    6280

    6680

    6850

    7100

    7460

    7960


    Hot recovery


    Refrigerant Charge (Kg)

    120

    128

    152

    156

    170

    184

    202

    Heat Reclaimed Volume (KW)

    107

    117

    139

    147

    161

    176

    190


    Heat Recovery

    Dia.of Pipe (inch)

    2-1/2"

    2-1/2"

    2"×2

    2"×2

    2"×2

    2"×2

    2"×2

    Water Side Max Pressure (MPa)

    1

    Reclaimed Water Flow (m3/h)

    18.5

    20.2

    23.9

    25.3

    27.7

    30.2

    32.6

    Water Pressure drop (kPa)

    26

    26

    27

    27

    30

    30

    34

    Total Weight (Kg)

    5170

    5310

    6720

    6910

    7100

    7540

    7960

    Running Weight(Kg)

    5530

    5840

    7360

    7580

    7820

    8400

    8780


    Note :


    1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃

    Chilled water inlet/outlet temp. 12℃/7℃, Fouling factor: 0.088㎡.°C/KW.

    2. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃

    Hot water inlet/outlet temp. 40℃/45℃; Hot water range: 45℃~45℃;

    2. Chilled Water Range: 5~20℃; Lowest Ambient Temperature: -5℃~43℃;

    3. Heat recovery unit water in/out temperature: 50℃/55℃;

    4.Changes of Specification for lmprovement May Be made without Notice.



    Advantage :


    Wide capacity range:


    1) The various type unit with range of cooling capacities from 358KW – 632KW;

    2) Each one has cooling only and cooling (heating) type;

    3) There are integrity and modular structure;

    4) Each one has regular computer control type and luxury computer control type;

    5) Provide optional components of auxiliary electrical heater, build-in water pump, and paddle flow switch

    etc. according to customer requirements.

    6) The unit may use no-standard refrigerant. It may be low water temperature type glycol for air cooled water

    chiller unit, or double refrigerants unit, air cooled compress condensing unit, etc. Please contact us for detail.


    The unit has high efficient, less energy consume, and low operating fee features.


    Golden Company imports brand high EER semi-hermetic crew type compressor, condenser, and cooling

    accessories from world and adopt advance technology in air conditioning and control. High quality process

    equipments and testing-center to ensure the units have energy saving and reliable features.


    Unit protection components


    The units have thermal protection switch, overload relay, high/low pressure switch, paddle flow switch and

    delay-starting protection devices to ensure unit runs under safety, reliable working condition and unit is easy to

    maintain and repairing.


    Modular design


    Multi-modular units adopt module combined structure to increase unit’s flexibility in transportation, installation,

    adjustment and maintain and reduce fee for transportation, installation and equipment maintain.


    Super low noise, operating quietly


    1) Semi-hermetic screw compressor has operating steady, low noise, and less vibration features.

    2) Brand condensing axial fan is used in the unit. The blades and exterior-rotor motor design integrally.

    The unit structure is simply with good air dynamic features and to ensure fan works under low noise and

    high efficiency.


    Advance control system, steady quality and reliable features.


    1) Micro-computer control intelligently, English display, and friendly interface. Operating information is clear at a

    glance.

    2) High automatic management with completely features to realize unit start up and shut down, timing control,

    water pump control, malfunction alarm and self-diagnosis features. It has RS485/RS232 communication

    port and convenience for centralize controlling and lone distance monitoring and long distance control.

    3) Micro-computer and electrical control elements are brand products and imported from world. The products has

    good quality, and reliable features

    4) Micro-computer controller defrosts intelligently with accuracy and efficiency. The controller also has self-diagnosis,

    energy management; anti-freeze and operating mode automatically control abilities. The unit has protections

    of high/low pressure, anti-freeze, oil temperature, overload, phase sequence, and water lacking to ensure

    unit run safety.


    Nice outline


    1) Air-cooled condenser with upside down M shape layout to improve space using ratio, heat exchange area

    of air-cooled condenser and to reduce unit overall size;


    2) The components and system pipes layout reasonable.


    3) The shell of the unit pained with statically treatment. The color of shell may design by customer when

    order is placed. The stainless steel plate is also available for shell.


    Save indoor space.


    1) The unit may install on roof of the building, ground or other location, where does not need equipment room.


    2) The unit uses high efficient heat exchanger. It adopts outdoor structure design and system matching with

    small volume, lightweight, and less area occupied.


    Easy to maintenance


    1) The installation of the unit is flexible. It can control at job site and long-distance


    2) Open type structure is convenience for maintenance and reduces service space.


    Golden refrigeration equipment CO.,LTD air source heat pump series:


    1 . Air source water chiller ( cooling only )

    2 . Air source heat pump ( cooling and heating or heating )

    3 . Air source water chiller / heat pump ( within heat recovery )

    1. Low temperature ambient air source Heat Pump
    Quality Hot Water Air Sourced Heat Pump Air Cooled Chilled Water System for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Dongguan Golden Refrigeration Equipment Co.,Ltd
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0